Structural Guide

Structural loads, structural analysis and structural design are simply explained with the worked example for easiness of understanding. Element designs with notes and discussions have added to get comprehensive knowledge. Also, construction materials, shoring system design, water retaining structures, crack width calculations, etc. have discussed in addition to other aspects. 

Cantilever Slab Design

Cantilever Slab Design Calculation & Procedure

Design of cantilever slab to Eurocode 2

  •          Span of slab 1.5m
  •          Variable load 4kN/mm2
  •          Slab thickness 175mm
  •          Fck 25N/mm2     fyk  500N/mm2
  •          Cover to the reinforcements 25mm
  •     Office building 

Slab loading

Self weight   = 175x25x10-3 = 4.375kN/mm2

Ultimate load                     = 1.35gk+1.5qk = 1.35×4.375+1.5×4 = 11.91 kN/mm2                                             
Bending moment  

n = 11.91 kN/mm2                                             
Bending moment  

M                                 = 11.91*1.5*1.5/2  = 13.4 kNm

Assume T10 bars used for the span

Effective depth          = 175-25-5  = 145 mm

Reinforcement

K                                     = M/bd2fck=13.4×10^6/(1000×145^2×25)=0.0255

K’                                     = 0.60δ-0.18δ2-0.21

No redistribution ,Therefore

δ                                       =1

k’                                      =0.21

k’>kCompression reinforcement is not required

Z                                       = (d/2)*(1+(1-3.53k)^0.5) ≤ 0.95

d = (145/2)*(1+(1-3.53*0.0255)^0.5) ≤ 0.95*145= 141.66 > 137.75 Therefore

Z                                          = 137.75

As                                      = M/0.87fyk*Z= 13.4*10^6/(0.87*500*137.75) = 224 mm2/m                                                

Provide T10 @ 200mm C/C (As pro. = 393mm2/m

Check for deflection (same method as two way slab)

Allowable span/d eff.    = (l/d)*F1*F2*F3

ρ                                          = As req. /bd

For cantilevered slab

K                                          = 0.4

ρ o                                        = (fck ^.5)/1000 = (25^.5)/1000  = 0.005ρ= 224/ (1000*145)  = 0.00154

Ρ0 > Ρ

Then

l/d                                          = K{11+[1.5*(fck^0.5) ρ o/ ρ ]+ 3.2*(fck^0.5)*[( ρ0/ ρ)-1]^1.5}= K{11+[1.5*(25^0.5)0.005/0.00154]+ 3.2*(25^0.5)**[(0.005/0.00154) – 1]^1.5}  = 35.69

Normal slab

F1                                           = 1

Span is less than 7m

F2                                           = 1

F3                                           = 310/σs ≤ 1.5         

σs                                          = (fyk/γs)(As,req/As,prov)(SLS Loads / ULS loads)(1/δ)

                                              =  (fyd)(As,req/As,prov)(gk+ Ψ2qk) /(γgk + γqk)(1/δ)

σs                                          = (500/1.15)(224/393)(4.375+0.3*4) /(1.35*4.375 + 1.5*4)(1/1)  = 116.1 N/mm2

F3                                = 310/116.1 = 2.67 ≥ 1.5

Hence,

F3                                = 1.5                              

Allowable span/d eff.    = 35.69*1*1*1.5  = 53.54

Actual span/ d eff.           = 1500/145   = 10.34

Deflection check is ok.

Share
Scroll to Top